# EN 18031 testing for connected products.

> EN 18031 is the harmonised standard series for the cybersecurity requirements of the Radio Equipment Directive, Article 3(3)(d), (e) and (f). An assessment has two sides: a conceptual one, whether the design of each security mechanism is sufficient, and a functional one, whether the device really behaves that way. Zyberum checks which parts and requirements apply to your product, finds the gaps, tests the device and documents the result. The declaration of conformity stays with you as the manufacturer. Where the restrictions of Implementing Decision (EU) 2025/138 apply, a notified body has to be involved; Zyberum is not a notified body.

EN 18031 for radio equipment: applicability check, gap analysis per mechanism, security testing against the assessment criteria and the technical documentation.

Source: https://zyberum.com/en-18031-testing

Since 1 August 2025 radio equipment placed on the EU market has to meet the cybersecurity requirements of the Radio Equipment Directive. We assess your device against EN 18031, test what the standard asks to be tested and write the documentation your declaration of conformity rests on.

## From applicability to documentation

### Applicability check

Which of the three parts apply, and which requirements the decision trees rule in or out for your device. The reasoning is written down, because it is part of the evidence.

### Gap analysis

Every mechanism of the standard against your design: access control, authentication, secure update, secure storage, secure communication, resilience, cryptographic keys and the rest.

### Device testing

The functional assessment on the real device: interfaces, firmware, update path, radio and the app or cloud it talks to.

### Fixes that pass

Concrete changes for the gaps we find, such as per-device credentials, signed updates and a boot chain that checks them, and a retest when they are in.

### Technical documentation

Assessment report per requirement with the decision tree answers, the test evidence and the open points, in the structure the standard uses.

### Ready for the CRA

The Cyber Resilience Act covers the same ground and more. We show which EN 18031 results carry over and what is still missing.

## Four steps to a documented result

1. **Scope.** One call and your product description: device, interfaces, intended use, existing documents. You get a fixed-scope offer.
2. **Assess the design.** We work through the decision trees and the conceptual assessment with your developers and list the gaps by mechanism.
3. **Test the device.** We test production units in our lab against the functional assessment criteria and beyond them where an attacker would not stop.
4. **Document and retest.** You receive the assessment report and a prioritised fix list. After your changes we retest and update the report.

## Where devices fail EN 18031

Three findings come up again and again. Shared or empty default passwords: with them a device cannot rely on the presumption of conformity at all. Updates that are not authenticated, or a boot chain that does not check them. And debug interfaces or services that are still open on production units.

None of this is visible in a design document. It shows on the bench, which is why the standard asks for a functional assessment and why we test the device you actually ship.

- Wi-Fi, Bluetooth, Zigbee, LTE and proprietary radio
- Consumer IoT, wearables, toys, gateways, industrial radio modules
- Hardware, firmware, app and cloud in one assessment
- Results reusable for CRA evidence

**What we do not do**

- We are not a notified body and issue no certificates
- The declaration of conformity is yours
- We never test without written authorisation

## EN 18031 gap checklist

The questions we ask in the first workshop, per mechanism, as a PDF. Go through it with your developers and you know where you stand before any test.

- All mechanisms of parts 1 to 3
- The restrictions that rule out self-declaration
- The findings that fail devices most often

PDF: /downloads/en-18031-gap-checklist.pdf

## FAQ

**Which products need an EN 18031 assessment?**

Radio equipment that can communicate over the internet falls under Article 3(3)(d) and EN 18031-1. If it processes personal data, or is a toy, childcare or wearable device, EN 18031-2 applies too. Equipment that handles money or virtual currency adds EN 18031-3. A Wi-Fi smart plug typically needs parts 1 and 2.

**Can we declare conformity ourselves?**

Yes, where you apply the standards in full and none of the restrictions in Implementing Decision (EU) 2025/138 applies. Where one applies, for example because the user may operate the device without setting a password, you cannot rely on the presumption of conformity and need a notified body for that requirement. We tell you in the first call which case you are in.

**Is a penetration test the same as an EN 18031 assessment?**

No. A penetration test looks for ways in. An EN 18031 assessment goes through each requirement of the standard, documents the decision tree answers and checks design and implementation against the assessment criteria. We combine both, because a device can meet every criterion and still have an exploitable flaw.

**What does it cost?**

It depends on the number of interfaces and on how much documentation exists. A gap analysis for one product is a matter of days; device testing follows the ranges for IoT products on our price page. You get a fixed-scope offer after the first call.

**Do you issue a certificate?**

No. The Radio Equipment Directive knows CE marking and the declaration of conformity, not security certificates. You receive an assessment report with the evidence. If a notified body has to be involved, our report is the preparation for it.

---
Zyberum GmbH. Canonical page: https://zyberum.com/en-18031-testing
