Skip to content
Zyberum Cyber Security Firm
Menu

EN 18031 · Radio Equipment Directive

EN 18031 testing for connected products.

Since 1 August 2025 radio equipment placed on the EU market has to meet the cybersecurity requirements of the Radio Equipment Directive. We assess your device against EN 18031, test what the standard asks to be tested and write the documentation your declaration of conformity rests on.

  • EN 18031-1, -2 and -3
  • Design review and device testing
  • Documentation for your declaration

In short

EN 18031 is the harmonised standard series for the cybersecurity requirements of the Radio Equipment Directive, Article 3(3)(d), (e) and (f). An assessment has two sides: a conceptual one, whether the design of each security mechanism is sufficient, and a functional one, whether the device really behaves that way. Zyberum checks which parts and requirements apply to your product, finds the gaps, tests the device and documents the result. The declaration of conformity stays with you as the manufacturer. Where the restrictions of Implementing Decision (EU) 2025/138 apply, a notified body has to be involved; Zyberum is not a notified body.

What we do

From applicability to documentation

Applicability check

Which of the three parts apply, and which requirements the decision trees rule in or out for your device. The reasoning is written down, because it is part of the evidence.

Gap analysis

Every mechanism of the standard against your design: access control, authentication, secure update, secure storage, secure communication, resilience, cryptographic keys and the rest.

Device testing

The functional assessment on the real device: interfaces, firmware, update path, radio and the app or cloud it talks to.

IoT penetration testing

Fixes that pass

Concrete changes for the gaps we find, such as per-device credentials, signed updates and a boot chain that checks them, and a retest when they are in.

Technical documentation

Assessment report per requirement with the decision tree answers, the test evidence and the open points, in the structure the standard uses.

Ready for the CRA

The Cyber Resilience Act covers the same ground and more. We show which EN 18031 results carry over and what is still missing.

CRA compliance

How a project runs

Four steps to a documented result

  1. 01

    Scope.

    One call and your product description: device, interfaces, intended use, existing documents. You get a fixed-scope offer.

  2. 02

    Assess the design.

    We work through the decision trees and the conceptual assessment with your developers and list the gaps by mechanism.

  3. 03

    Test the device.

    We test production units in our lab against the functional assessment criteria and beyond them where an attacker would not stop.

  4. 04

    Document and retest.

    You receive the assessment report and a prioritised fix list. After your changes we retest and update the report.

What we see

Where devices fail EN 18031

Three findings come up again and again. Shared or empty default passwords: with them a device cannot rely on the presumption of conformity at all. Updates that are not authenticated, or a boot chain that does not check them. And debug interfaces or services that are still open on production units.

None of this is visible in a design document. It shows on the bench, which is why the standard asks for a functional assessment and why we test the device you actually ship.

  • Wi-Fi, Bluetooth, Zigbee, LTE and proprietary radio
  • Consumer IoT, wearables, toys, gateways, industrial radio modules
  • Hardware, firmware, app and cloud in one assessment
  • Results reusable for CRA evidence

FAQ

EN 18031 FAQ

Which products need an EN 18031 assessment?

Radio equipment that can communicate over the internet falls under Article 3(3)(d) and EN 18031-1. If it processes personal data, or is a toy, childcare or wearable device, EN 18031-2 applies too. Equipment that handles money or virtual currency adds EN 18031-3. A Wi-Fi smart plug typically needs parts 1 and 2.

Can we declare conformity ourselves?

Yes, where you apply the standards in full and none of the restrictions in Implementing Decision (EU) 2025/138 applies. Where one applies, for example because the user may operate the device without setting a password, you cannot rely on the presumption of conformity and need a notified body for that requirement. We tell you in the first call which case you are in.

Is a penetration test the same as an EN 18031 assessment?

No. A penetration test looks for ways in. An EN 18031 assessment goes through each requirement of the standard, documents the decision tree answers and checks design and implementation against the assessment criteria. We combine both, because a device can meet every criterion and still have an exploitable flaw.

What does it cost?

It depends on the number of interfaces and on how much documentation exists. A gap analysis for one product is a matter of days; device testing follows the ranges for IoT products on our price page. You get a fixed-scope offer after the first call.

Do you issue a certificate?

No. The Radio Equipment Directive knows CE marking and the declaration of conformity, not security certificates. You receive an assessment report with the evidence. If a notified body has to be involved, our report is the preparation for it.

Get started

Find out in 15 minutes what EN 18031 means for your device

Tell us what the device does and how it connects. You learn which parts apply, whether a restriction affects you and what an assessment would cover.

  • Which of the three parts apply to your product
  • Whether you can self-declare or need a notified body
  • A fixed-scope offer after the call
Tom Zaubermann

Your call is withTom ZaubermannFounder & CEO, Zyberum

Call us: +49 176 439 17074info@zyberum.com

Or send us a message

We reply within one business day.

Call usScope your EN 18031 assessment

Pick a time that suits you

Open in a new tab